A-1 Non-Insulated Waterproofing Assembly
A-3 Non-Insulated Waterproofing Assembly with Fully Adhered Cap Sheet
A-5 Insulated Waterproofing Assembly with Foam Insulation & Coverboard
A-5B Plaza Waterproofing Assembly with Foam Insulation & Coverboard
A-8 Roof Recovery Assembly
A-11 Insulated Roof Recovery Waterproofing Assembly with Foam Insulation & Coverboard
A-13 PRMA Waterproofing Assembly with Overburden
A-15 PRMA Waterproofing Assembly with Fully Adhered Cap Sheet
A-16 Waterproofing Assembly with Overburden
A-18 Plaza Waterproofing Assembly with Pedestal-Mounted Paver Overburden
A-19 Plaza Waterproofing Assembly with Solid Overburden
A-21 Balcony Waterproofing with Surfacing Assembly
A-22 Balcony Waterproofing Assembly with Overburden
A-23 Balcony Waterproofing Assembly with Insulation & Overburden
A-24 Planter Box Waterproofing Assembly
A-25 Landscape Waterproofing Assembly
A-26 Landscape Waterproofing Assembly with Insulation
A-27 Split-Slab Below-Grade Waterproofing Assembly
A-28 Below-Grade Waterproofing Assembly with Overburden
A-29 Interior Floor Waterproofing Assembly
A-30 Interior Floor Waterproofing Assembly with Overburden
A-31 Interior Floor Waterproofing Assembly with Overburden (Kemperol 022)
B-6 Planter Box Waterproofing Concrete Masonry Knee Wall
B-6A Planter Box (Engaged) Waterproofing Flashing
B-6B Planter Box Waterproofing Concrete Masonry Building Wall
CURB/PAD ENCAPSULATION FLASHING 6" MIN. SIMPLEX - KDP 7
DOOR SILL FLASHING- KDM 3A
DRIP EDGE FLASHING- KDE 1
FIELD FABRICATED OUTSIDE CORNER FLASHING- KDM 1
FIELD FABRICATED PIPE PENETRATION FLASHING - KDP 1
FIELD FABRICATED WARM PIPE PENETRATION FLASHING- KDP 2
GUTTER EDGE FLASHING - KDE 3
HORIZONTAL (IN-LINE) EXPANSION JOINT FLASHING- KDJ 2
HORIZONTAL TO VERTICAL TRANSITION EXPANSION JOINT FLASHING- KDJ 1
HORIZONTAL TO VERTICAL TRANSITION EXPANSION JOINT W/ CUT-IN REGLET - KDJ 1A
INSIDE CORNER FLASHING - KDM 2
INSULATED MODIFIED BITUMEN ASSEMBLY- KD 1
INSULATED RECOVER MODIFIED BITUMEN ASSEMBLY- KD 4
IRREGULAR PENETRATION ANGLE FLASHING- KDP 3
IRREGULAR PENETRATION UNI-STRUT CHANNEL FLASHING - KDP 5
KDI 1
KDI 2
MECHANICAL MOISTURE VENT FLASHING K.S.A. - KDP 6
NAILABLE MODIFIED BITUMEN ASSEMBLY- KD 2
NON-INSULATED RECOVER MODIFIED BITUMEN ASSEMBLY- KD 4A
NON-NAILABLE MODIFIED BITUMEN ASSEMBLY- KD 3
ONE PLY BASE FLASHING W/ COUNTER FLASHING- KDB 1E
ONE PLY BASE FLASHING W/ CUT-IN REGLET- KDB 1D
ONE PLY BASE FLASHING- KDB 1C
ONE PLY BASE W/ COUNTER FLASHING- KDB 5A
ONE PLY CURB FLASHING - KDP 8
PARAPET WALL W/ METAL COPING CAP (OPTIONAL) SIMPLEX- KDB 3A
PARAPET WALL W/ STONE COPING CAP- KDB 4A
RAISED DRIP EDGE FLASHING- KDE 2
ROOF DRAIN FLASHING- KDD 1
ROOF DRAIN FLASHING- KDD 1i
SCUPPER DRAIN FLASHING- KDD 2
SHOWN KDI-3 WOOD DECKS BASE SHEET ATTACHMENT TO- KDI 3
STEEP SLOPE APPLICATION- KD 5
STEEP SLOPE APPLICATION- KD 5A
THRU-WALL SCUPPER FLASHING- KDD 3A
TWO PLY BASE FLASHING W/ CUT-IN REGLET- KDB 2D
TWO PLY BASE FLASHING- KDB 2C
TWO PLY BASE W/ COUNTER FLASHING- KDB 2E
WIDE FLANGE FLASHING- KDP 4
IA-1 Diamond-In-Square Insulation Attachment Pattern
IA-2 Urethane Adhesive Ribbon Insulation Attachment Pattern
IA-3 Cover Board Joint Stripping-In Detail
HW-1 Roof Zone Layout
HW-2 Urethane Adhesive Ribbon Insulation Attachment Pattern
HW-3 Fastener & Plate Insulation Attachment Pattern
HW-4 Roof Edge Securement
J-1 Horizontal to Vertical Transition Expansion Joint Flashing
J-1A Horizontal to Vertical Transition Expansion Joint with Cut In Reglet
J-1B Horizontal to Vertical Transition Expansion Joint with Counterflashing
J-1R Horizontal to Vertical Redline Expansion Joint Flashing
J-2 Horizontal (In-Line) Waterproofing Expansion Joint
J-3 Horizontal (In-Line) Waterproofing Expansion Joint with Sealant
J-3R Horizontal Redline Waterproofing Expansion Joint
J-4 Flashing at Vehicular Traffic Joint